Problem
The DA12 is powered on and its input is connected, but no time-code signal is detected at one or more outputs.
Possible causes
- Gain is too low: the output signal may be too weak for the receiving device to detect.
- The output is shorted: a damaged cable, connector or connected device may short the signal.
- Too much resistance on the line: cable problems or poor connections may weaken the signal reaching the receiver.
- A faulty output: an individual DA12 output may not be working.
Troubleshooting steps
- Try another output in the same bank. Move the same cable and receiver to another output. If it works there, the original output may be faulty.
- Check the output cable. Look for loose connections or damaged connectors, then try a known-working cable. If the replacement works, repair or replace the original cable.
- Try the other output bank. Test A and B independently, connecting the source to the matching input for each bank. Then use the Select switch to couple the banks, with input A feeding both, and try an output in each bank again.
- Increase gain gradually. Turn the affected bank's gain control clockwise in small increments while watching for the receiver to detect time code. A and B have separate gain controls; adjust the bank being tested.
If the problem persists
Contact Masterclock Support. Tell them which outputs and banks you tried, whether a different cable helped, and whether increasing gain changed the result.